The RACGP Standards for general practices (6th edition) bring cybersecurity, privacy, digital health and artificial intelligence into sharper focus for Australian general practices. For practice owners and managers, the challenge is not simply writing another policy. It is understanding which requirements apply, checking whether safeguards actually work, and keeping evidence of the steps taken.
This guide focuses on selected requirements most relevant to cybersecurity and AI readiness. It does not cover every accreditation criterion, and it is not a substitute for reading the official Standards. The practical examples below are suggestions for reviewing your practice—not a new mandatory checklist issued by the RACGP.
Busy practice? Start with these 6 checks
You do not need to be an IT expert. Use these questions to find out what your practice already does well and what needs attention. These are Veytrix practical prompts, not an official RACGP priority ranking.
Can we recover patient records?
Check whether backups work and how the clinic will care for patients during an IT outage.
Ask for: latest successful restore test and downtime plan.Who can see patient information?
Check individual staff logins, access permissions and privacy responsibilities.
Ask for: current user access list and privacy policy.What if we have a cyberattack?
Make sure the team knows whom to call, how to respond and how to continue essential care.
Ask for: incident response plan and emergency contacts.Who owns cybersecurity?
Know what the IT provider manages and who inside the practice oversees digital governance.
Ask for: named contacts and documented responsibilities.Are our digital tools safe?
Review telehealth, messaging, patient portals and how these tools handle patient information.
Ask for: approved tools and vendor arrangements.Are we using AI responsibly?
If using AI scribes or clinical AI, review patient consent, data handling and clinician oversight.
Ask for: AI consent process and vendor review.What should the practice manager do next?
Use this table at your next meeting with the practice owner, clinical lead or IT provider. The examples are practical starting points; what applies will depend on your clinic.
| What to check | Who to ask | Evidence to request |
|---|---|---|
| Patient record backups | IT provider | Latest successful backup restoration test |
| Cyber incident response | Practice manager / IT provider | Response plan and emergency contact list |
| Patient data access | Practice manager / IT provider | Staff access list and leaver process |
| Privacy arrangements | Privacy lead / practice manager | Current privacy policy and staff guidance |
| Digital health tools | Practice manager / vendor | Tool list, approval and data-handling arrangements |
| AI tools, if used | Clinical lead / vendor | Consent process, clinical oversight and vendor review |
One useful habit: For each gap, write down what needs fixing, who owns it and when it will be reviewed.
How the RACGP topics fit together
- F8 – Information security: ICT continuity, security responsibilities, digital communications and records management.
- F9 – Confidentiality and privacy: privacy policies, patient information and authorised access.
- F10 – Digital health technologies: evaluation, implementation, consent and access to technical expertise.
- F11 – Artificial intelligence: patient consent, clinical oversight and evaluation of AI systems.
- Evidence matters: document what is in place, who owns it, and when it was last reviewed or tested.
What does the RACGP 6th Edition mean for cybersecurity?
The Standards describe what general practices should achieve in areas affecting safe, high-quality care. Cybersecurity is part of that picture because a privacy breach, unavailable clinical system or failed backup can directly affect patients. The 6th Edition also addresses the adoption of digital health technologies and AI.
Practices should distinguish between criteria and indicators, which describe expectations, and guidance or examples, which help explain possible ways to meet them. An example such as a particular backup schedule should not automatically be presented as a standalone accreditation requirement. The official document should always be the reference point. In this guide, items marked indicator are listed under a criterion in the Standards, and items marked guidance come from the Standards' supporting text.
A useful first step is to map existing policies, systems and evidence to the relevant criteria. A practice may already have many safeguards in place; the missing piece may be documented ownership, a recent test or a clear record of staff training.
F8 – Information security: protect systems and plan for disruption
Check your backups, recovery plan, incident contacts and who is responsible for IT security.
What to do next: Ask your IT provider for a recent successful backup restore test and review the downtime plan with staff.
Read the detailed RACGP criteria and supporting guidance
F8.A addresses ICT continuity, protection and recovery planning, including a cybersecurity incident response plan and testing. A practical review should ask whether the practice can continue delivering care if its appointment system, clinical software or internet connection becomes unavailable.
For example, a clinic may have automatic backups but no recent evidence that patient records can be restored. Another clinic may rely on an external IT provider without knowing who decides to isolate a compromised device or notify affected patients. Both situations warrant review.
What the Standards list under F8.A (indicators)
- A documented ICT continuity, protection and recovery plan that is regularly tested and includes a cyber security incident response plan.
- A backup log, operated by the practice or a contracted provider.
- Up-to-date antivirus protection and hardware and software firewalls.
- Secure offsite or cloud backup of information, and the ability to restore from it.
- Procedures to inform patients when a data breach affects their personal information.
What the supporting guidance adds (Table 6 and the F8 text)
The guidance describes what a plan could include, so use it to shape your controls rather than as a separate pass-or-fail list:
- An incident response plan that covers detecting and sizing a breach, containment, recovery of essential systems, notifying patients and authorities, and a post-incident review.
- Daily or more frequent backups, ideally automated, with regular tests that backups are readable and restorable.
- Signed agreements with ICT providers that set out their security obligations, including remote access.
- Email scanning for malicious attachments and links, and timely automatic updates for antivirus and software patches.
- Ongoing staff training on cyber safety, malware and reporting incidents.
- Knowing your legal obligations and who to contact in a cyber emergency. The Standards name the Australian Signals Directorate, state and federal police and the Department of Home Affairs.
Under F2.A, the practice also needs a tested plan so the clinical team can keep delivering care where feasible if ICT stops working. The guidance gives simulating cyberattacks or access issues as one way to test ICT resilience.
F8.B addresses responsibility for security and digital governance. The practice needs a named person, either a team member or a contracted provider, with primary responsibility for the security of its electronic systems. If that person is an external provider, a member of the practice team must hold primary responsibility for digital governance. The privacy policy also needs to document how health information is stored and accessed, including remote access if it applies. F8.C–F8.E cover digital communications, social media and records handling. The guidance for records adds that hard drives and other storage media, including printers and photocopiers, should be wiped before disposal, and that health information, including backups, is best stored in Australia where possible. If anything is stored overseas, the privacy policy should say so and patients should be told. F8.F is identified as an aspirational criterion concerning patient information about digital communication tools, and should not be treated as a required accreditation criterion.
The Standards also provide supporting information-security guidance, including backup practices and supplier arrangements. Those examples can help a clinic choose controls, but the exact method should be appropriate to its systems and risk.
F9 – Confidentiality and privacy: know who can access patient information
Check individual staff accounts, permissions, privacy policies and how information is shared.
What to do next: Ask for a current list of staff access permissions and confirm that former staff accounts are disabled.
Read the detailed RACGP criteria and supporting guidance
Under F9.A, practices should review their privacy policy, how patients are informed about it, and how privacy responsibilities are managed. F9.B focuses on protecting health information from unauthorised access, including individual access to clinical information systems.
The indicators under F9.A include a privacy policy consistent with the Australian Privacy Principles that patients are told about, a team member with primary responsibility for privacy, confirmation that the team understands and applies the policy, and informing patients about the practice's data breach protocols. Under F9.B, only authorised team members may access the clinical information system, each through a unique individual login matched to their level of authority. The privacy policy needs to describe how access levels are decided and given, and prescription forms and other official documents must be stored securely. The Standards' glossary notes that a unique login can use passwords, multifactor authentication or biometrics.
A policy alone does not show that access is controlled. Ask whether every staff member uses an individual account, whether access matches their role, and whether permissions are removed when a person leaves the practice. Consider reception, locums, external contractors and remote access—not only doctors.
Electronic communications also need attention. When sending health information, practices should consider secure messaging or encryption and the circumstances in which informed patient consent is relevant to less secure channels. The Standards' secure-transmission indicator sits under F9.A, even though communication processes also relate to F8.C.
For wider legal context, the Privacy Act and APP 11 guide explains reasonable steps to protect personal information. RACGP accreditation standards and Australian privacy-law obligations are related, but they are not interchangeable.
F10 – Digital health technologies: assess tools before rollout
Telehealth, patient portals and messaging tools can affect patient privacy and clinical workflows.
What to do next: Keep a list of digital tools and record who approved each one and what patient information it handles.
Read the detailed RACGP criteria and supporting guidance
F10.A addresses processes for assessing, implementing and managing digital health technologies, including their impact on patients and the practice team. Technologies might include telehealth systems, patient portals, secure messaging, mobile applications or remote monitoring tools.
Before introducing a new product, identify the information it collects, where that information is held, who can access it, how the vendor supports the product, and what happens if it becomes unavailable. Consider patient consent and whether staff have access to appropriate technical expertise.
These reviews are not limited to large projects. A seemingly simple online form, appointment platform or transcription service can introduce new access paths and data-sharing arrangements. Keep a short decision record showing the risks considered, approval given and follow-up owner.
F11 – Artificial intelligence: consent, accountability and ongoing review
AI scribes and clinical AI need appropriate patient consent, privacy safeguards and clinician review.
What to do next: Ask the clinical lead to confirm consent procedures, vendor data handling and who checks AI-generated notes.
Read the detailed RACGP criteria and supporting guidance
F11.A and F11.B address the safe and appropriate use of AI in general practice. This is especially relevant to clinics exploring AI scribes, clinical decision-support tools and other AI-enabled services. Practices that do not use AI should still confirm how applicability is determined against the official criteria rather than assuming every AI-related question is automatically satisfied.
What the Standards list under F11.A and F11.B (indicators)
- Processes for clinicians to obtain and document informed patient consent when care will involve AI.
- De-identification or anonymisation when AI tools process patient data, and no use of identified data unless it is clinically necessary, explicitly authorised and backed by documented governance and consent.
- Discussion with the team about practical implications and training needs.
- Governance processes covering accountability and compliance with legislation, and documented clinical oversight of AI output. Clinicians remain accountable for care decisions supported by AI.
- A process to assess and evaluate each AI tool, including risk mitigation, before it is implemented (F11.B).
- Ongoing monitoring, review and quality improvement so AI tools stay safe and effective (F11.B).
Patient consent and transparency
Before using an AI tool in patient care, consider what patients are told about its purpose, the information it processes and how it may affect care. Document informed consent where required and establish a practical way to respond when a patient does not want the tool used. Supporting guidance discusses withdrawal, choice and alternative care pathways.
Clinical oversight and vendor due diligence
AI-generated notes and recommendations can be inaccurate or incomplete. A clinician should be able to review, question and override outputs, with responsibility for clinical decisions remaining clear. Evaluate the vendor's security arrangements, retention and secondary use of data, access controls and contractual terms before deployment. The F11 guidance suggests asking whether the vendor confirms compliance with the Privacy Act and Australian Privacy Principles, whether collected data can be used or sold for secondary purposes, and how patient data is encrypted, stored and destroyed. When AI tools are provided by third parties, the practice remains responsible for their safe and appropriate use.
Some AI products may be regulated as medical devices under Australian law. The Therapeutic Goods Administration (TGA) says not all digital scribes are medical devices: tools limited to transcription and documentation are unlikely to meet the definition, while features that analyse or interpret a consultation and generate diagnostic or treatment suggestions are more likely to. The TGA has also reported that some scribe suppliers had not considered whether medical device requirements applied to their products. Ask each vendor about the product's regulatory status, including Australian Register of Therapeutic Goods (ARTG) inclusion where it applies. Even where a tool is not a regulated device, the practice remains responsible for privacy, consumer law and cybersecurity.
Keep monitoring after implementation
Approval at purchase is not the end of the process. Establish who reviews incidents, changes to the tool, clinical performance, complaints and vendor updates. As a practical suggestion (not a Standards requirement), keep a register of approved AI tools and review it periodically. The official F11 guidance discusses assessment, evaluation and the ability to challenge AI output.
Related legal obligations outside the RACGP Standards
The following are legal requirements, not RACGP criteria. Whether they apply depends on your practice, so confirm with your legal adviser.
- Automated decision-making in your privacy policy (from 10 December 2026). Under changes to the Privacy Act, organisations covered by the Act that use computer programs to make, or substantially help make, decisions that could significantly affect a person's rights or interests will need to describe this in their privacy policy. Most AI scribe note-taking is unlikely to be a significant decision on its own, but review any tool that influences access to care, eligibility or billing, and check the OAIC's guidance.
- Ransomware payment reporting. Since 30 May 2025, businesses with an annual turnover of $3 million or more must report a ransomware or cyber extortion payment to the Australian Signals Directorate within 72 hours of making it, or of becoming aware that a payment was made on their behalf. Many larger clinics and medical centres will be above that threshold. Make sure your incident response plan says who decides and who reports.
Other RACGP criteria that support cyber readiness
Cybersecurity and information governance are not confined to F8–F11. Other relevant criteria include F2.A for emergency response and business continuity (cyber attacks are one of the unexpected events the Standards name), CG1.A for clinical information systems, and CG13.C–CG13.D for sharing patient information for research. Research-related requirements should be considered where the practice undertakes relevant activities, including de-identified information sharing and patient information or choice.
Because this article concentrates on cyber and AI, it is not a complete review of the RACGP 6th Edition Standards. Accreditation preparation should consider the full set of applicable criteria, including areas beyond information technology.
Detailed 10-point checklist (optional)
Open the full 10-point practice checklist
- Can we show an up-to-date ICT continuity and cyber incident response plan (F8.A, F2.A)?
- When did we last successfully restore critical information from backup (F8.A)?
- Who is accountable for ICT security and digital governance (F8.B)?
- Do staff have individual, role-appropriate access to clinical systems (F9.B)?
- Have we reviewed remote access, software updates and protective controls (F8.A, F8.B)?
- Does our privacy policy reflect how information is actually handled and shared (F9.A)?
- Have we reviewed the security and data-handling terms of our external providers (F8.A, F11.A)?
- Do we assess digital health tools before implementing them (F10.A)?
- If we use AI, can we demonstrate appropriate patient consent, clinical oversight and vendor review (F11.A, F11.B)?
- Do we record gaps, assign owners and follow through on corrective actions?
Use these questions as a discussion starter with your practice team and IT provider. They are Veytrix's practical prompts, not a verbatim RACGP checklist.
For each answer, record the evidence, the person responsible and a realistic review date. Prioritise weaknesses that could expose patient records, disrupt care or prevent recovery from an incident.
Try the free RACGP 6th Edition Cybersecurity & AI Readiness Assessment
To make this review easier, Veytrix Cyber Security has developed a free, independent RACGP 6th Edition Cybersecurity & AI Readiness Assessment. It covers 15 selected criteria through detailed, plain-English checks across ICT resilience, privacy, digital health and AI governance, based on the indicators and supporting guidance in the Standards.
Free GP clinic readiness check
Review your current practices, identify self-reported gaps and print or save the results as a PDF. No registration is required, and assessment answers remain in your browser tab rather than being submitted to Veytrix.
Start the free RACGP readiness assessment →
Do not enter patient information. Results are indicative and not independently verified.
If you need an evidence-based technical review rather than a self-assessment, explore our healthcare cybersecurity assessment services. We help GP clinics identify security gaps and prioritise practical remediation, with reports written in plain English.
Frequently asked questions
Is my clinic assessed against the 6th Edition now?
Not yet. As at 19 November 2026, accreditation under the NGPA Scheme still uses the 5th edition, and transition arrangements will be published later. The Australian Commission on Safety and Quality in Health Care encourages practices to begin implementing the 6th edition, so preparing now is sensible.
Does the RACGP 6th Edition require every GP clinic to use AI?
No. The AI provisions address governance of AI where it is relevant to a practice's activities. Practices should read the official wording and consider applicability rather than treating AI adoption as compulsory.
Is a cybersecurity policy enough for RACGP readiness?
A policy is useful, but it does not replace working controls, staff awareness, tested continuity arrangements and supporting evidence. Practices should be able to explain how their documented processes operate in real situations.
Is the Veytrix tool an official RACGP accreditation assessment?
No. It is an independent, self-reported tool covering selected cybersecurity and AI-related criteria. It does not assess all accreditation requirements, verify evidence or determine compliance, and Veytrix is not affiliated with or endorsed by the RACGP.
Are backups enough to meet F8.A?
No. F8.A also looks for a tested continuity and recovery plan with a cyber incident response plan, a backup log, protection such as antivirus and firewalls, the ability to restore from offsite or cloud backup, and procedures to inform patients after a breach. A backup only helps if you can show it restores.
Where should a small GP clinic start?
Start by reviewing access to patient information, tested backups, incident response, privacy processes and any digital or AI tools in use. Document what is already working before deciding what to improve.
Official sources and further reading
- RACGP – Standards for general practices, 6th edition (table of contents, including F2, F8–F11, CG1 and CG13).
- RACGP – What practices need to know about the sixth edition.
- Australian Commission on Safety and Quality in Health Care – RACGP Standards 6th edition and the NGPA Scheme.
- OAIC – APP 11: Security of personal information.
- TGA – Software and artificial intelligence as medical devices.
- Explanatory Statement – Cyber Security (Ransomware Payment Reporting) Rules 2025.
- Veytrix – Cybersecurity for GP Clinics in Australia.
- Veytrix – Essential Eight for Australian Healthcare Practices.
Important disclaimer: This article provides general educational information about selected topics in the RACGP Standards for general practices (6th edition). It is not legal advice (including on the Privacy Act and Cyber Security Act matters mentioned above), a technical audit, an accreditation determination or a substitute for the full official Standards. Veytrix Cyber Security is independent and is not affiliated with, endorsed by or approved by the RACGP. Check current official guidance and obtain appropriate professional advice for your circumstances.